A fire rated steel door is not just a slab of metal; it's a complete life-safety system. Think of it as an engineered assembly where the door, frame, and hardware must work together perfectly. If even one component is wrong, the entire barrier fails. This is what separates a compliant, code-passing installation from a costly violation. This guide breaks down the critical specifications—from steel gauges and construction types to UL certification and NYC building codes—so you can confidently choose the right door for your project.
Quick Answer: A fire rated steel door is a tested and certified assembly, including the door leaf, frame, and hardware, designed to resist fire for a specific duration (20 minutes to 3 hours). Most commercial fire rated steel doors use 16- or 18-gauge Galvanneal steel, must carry a UL or WHI certification label, and are required in NYC stairwells, corridors, elevator lobbies, and apartment entry points under the 2022 NYC Fire Code and NFPA 80.
What Makes a Steel Door Fire Rated?
Not every steel door qualifies as fire rated. The critical distinction is certification. A fire rated steel door has been tested as a complete assembly, door, frame, and hardware, under controlled furnace conditions per ANSI/UL 10C (Standard for Positive Pressure Fire Tests of Door Assemblies). The assembly must resist fire penetration and maintain structural integrity for the rated duration.
The key standards governing fire rated steel doors include:
- NFPA 80: Standard for Fire Doors and Other Opening Protectives, covering installation, inspection, and maintenance
- ANSI/UL 10C: Positive pressure fire test standard for swinging door assemblies
- IBC (International Building Code): Sets requirements for where fire rated doors must be installed
- NFPA 252: Standard fire test methods for door assemblies
A steel door without a certification label from a nationally recognized testing laboratory, such as UL (Underwriters Laboratories) or WHI (Warnock Hersey/Intertek), is simply a steel door. It does not legally qualify as fire rated, regardless of how thick or heavy it is.
Inside a Fire Rated Steel Door: Construction Types
Fire rated steel doors are manufactured using several construction methods, each suited to different performance requirements. Universal Fireproof Door manufactures all of the following types in our Brooklyn facility.
Hollow Metal Doors
The most common type of fire rated steel door is the commercial hollow metal door. Despite the name, these doors are not empty. Two steel panels form the exterior shell, and the interior space is filled with a core material that provides insulation, sound dampening, and fire resistance. Hollow metal doors can achieve fire ratings from 20 minutes up to 3 hours depending on the core type and steel gauge used.
Steel-Stiffened Doors
Steel stiffened doors feature internal steel ribs welded between the face panels. This construction provides superior impact resistance and security while maintaining fire rating capabilities. These doors are ideal for high-traffic commercial environments, detention facilities, and areas where forced-entry resistance is required alongside fire protection.
Polystyrene-Filled Doors
Polystyrene core doors use expanded polystyrene insulation between the steel panels. This construction type delivers excellent thermal insulation, making it suitable for exterior applications or areas requiring temperature separation. Polystyrene-filled steel doors are commonly used where energy efficiency and fire protection must coexist.
Honeycomb Core Doors
Honeycomb core construction uses a kraft paper or aluminum honeycomb matrix sandwiched between steel panels. These doors are lighter weight than steel-stiffened alternatives while still meeting fire rating requirements of up to 90 minutes. They work well for interior applications in hospitals, schools, and office buildings where frequent operation is expected.

Residential vs. Commercial Fire Doors
The main difference between residential and commercial fire doors comes down to their daily demands and specific code requirements. A door in a high-traffic commercial building or hospital needs to withstand constant use and potential abuse. This is why you’ll often find steel-stiffened doors in these settings; their internal steel ribs provide superior durability and impact resistance that a standard residential door simply doesn't need. The focus for commercial doors is on maximum durability, security, and compliance with stringent fire codes for public spaces.
In contrast, while an apartment entry door in NYC must also meet strict fire-rating standards to ensure resident safety, it might also have different performance priorities. For example, energy efficiency is a bigger concern for homeowners, making a polystyrene-filled door an excellent choice for its thermal insulation properties. While both door types are certified fire-rated assemblies, their construction is tailored to the environment—balancing robust safety features with practical needs like insulation, sound dampening, and ease of use for the people who interact with them every day.
Steel Gauge Explained: What the Numbers Really Mean
The gauge of the steel used in a fire rated door directly affects its strength, weight, durability, and fire performance. Lower gauge numbers indicate thicker, heavier steel.
| Steel Gauge | Thickness (inches) | Typical Application |
|---|---|---|
| 20-gauge | 0.032" | Light-duty interior doors, standard openings |
| 18-gauge | 0.042" | Most common commercial fire rated doors |
| 16-gauge | 0.053" | High-security, high-traffic, maximum durability |
| 14-gauge | 0.067" | Detention, blast-resistant, extreme-duty |
18-gauge Galvanneal steel is the industry standard for most commercial fire rated steel doors. It provides the right balance of structural integrity, weight management, and fire resistance. For high-abuse environments like emergency exit doors or high-traffic commercial entries, 16-gauge steel offers additional impact and security performance.
Galvanneal steel (hot-dip galvanized and annealed) is preferred over standard cold-rolled steel because it provides superior corrosion resistance and accepts paint and primer more effectively. All fire rated steel doors should arrive with a factory-applied rust-inhibiting primer, ready for field painting.
Essential Hardware and Components for Fire Doors
A fire door’s rating isn’t just about the door itself; it’s about the entire assembly working in perfect harmony. The frame, hinges, latches, and seals are all critical components that must be rated and compatible to create a compliant fire barrier. If even one piece of hardware is incorrect, the entire system can fail during a fire and will certainly fail an inspection. Understanding these components is key to ensuring your building is safe and up to code. At Universal Fire Doors, we handle these details every day, ensuring every part of your fire door installation meets strict NYC regulations.
Intumescent Seals for Smoke Control
One of the most critical, yet often overlooked, components of a fire door assembly is the sealing system. Intumescent seals are a game-changer in a fire. As one expert notes, "Many steel fire doors have 'intumescent seals' that swell up when it gets hot, blocking smoke and dangerous gases." This is vital because smoke and toxic fumes can be just as deadly as the flames themselves. When exposed to heat, these strips expand to many times their original size, filling the gap between the door and the frame. This action effectively contains smoke, providing clearer escape routes and protecting building occupants. Ensuring your doors have properly installed, certified intumescent seals is a non-negotiable part of meeting fire code, especially in high-occupancy buildings like hotels and apartment complexes.
Mandatory Latching Hardware
A fire door is only effective if it stays closed during a fire. That’s why specific latching hardware is mandatory. According to industry standards, "Fire doors must close by themselves and latch shut automatically. You cannot use push/pull plates on them." This means every fire-rated door must be equipped with a closing device (a door closer) and a piece of hardware that positively latches the door into the frame. This could be a lockset, a panic bar, or a fire exit device. The latch ensures that the pressure created by a fire cannot force the door open. This is a common failure point we see during inspections, and our repair services often involve correcting improper or non-functional latching hardware to restore compliance.
Vision Lite Kits and Fire-Rated Glass
Many fire doors, especially those in corridors or classrooms, require windows for visibility. These openings, called vision lites, must not compromise the door's fire rating. You cannot use standard glass. As one manufacturer explains, "Fire-rated glass, like Pyroguard, Pilkington Pyrostop, or Vetrotech Contraflam, is essential. It can stop flames, smoke, and sometimes heat from passing through." This special glazing is tested and certified to withstand fire for a specific duration, just like the door itself. The size of the vision lite is also strictly regulated by NFPA 80 and depends on the door's overall fire rating. We help clients select the correct fire-rated glass and vision lite kit to balance safety requirements with the need for visibility.
"Pre-Hung" vs. Slab Doors
When purchasing a fire door, you’ll encounter the terms "pre-hung" and "slab." A slab is just the door itself. A pre-hung unit, on the other hand, is a complete package. As one supplier describes it, a "'pre-hung' option...means the door comes with the frame, hinges, and holes for the handle already set up." For fire-rated openings, choosing a pre-hung assembly is almost always the best practice. It ensures that the door, frame, and hardware preparations are all factory-certified to work together as a compliant system. This eliminates guesswork on-site and significantly reduces the risk of installation errors that could void the fire rating. It’s the most reliable way to guarantee a code-compliant commercial door replacement.
The Practicality of "Non-Handed" Doors
In the world of doors, "handing" refers to the direction the door swings (left or right). Ordering the wrong handing can cause major delays on a project. This is where non-handed doors offer a practical advantage. As noted by Trudoor, "The doors are 'non-handed,' meaning they can be set up to open either to the left or the right." This flexibility is incredibly useful on a busy job site. A non-handed door can be inverted to fit either a left-hand or right-hand swing, simplifying inventory for building managers and providing a safety net for contractors. While we can manufacture doors to any specific handing, offering non-handed designs provides a versatile solution that saves time and reduces potential headaches during installation.
Decoding Fire Ratings: From 20 Minutes to 3 Hours
Fire ratings indicate how long the door assembly can withstand fire exposure during standardized testing. The rating applies to the entire assembly, not just the door leaf.
| Fire Rating | Common Locations | Wall Rating Requirement |
|---|---|---|
| 20-minute | Corridor doors, room-to-corridor separations | 1-hour rated wall |
| 45-minute | Corridor to room doors, office partitions | 1-hour rated wall |
| 60-minute (1-hour) | Corridor doors, apartment entries, hospital rooms | 1-hour rated wall |
| 90-minute (1.5-hour) | Stairwell enclosures, exit corridors, elevator lobbies | 2-hour rated wall |
| 180-minute (3-hour) | Fire walls, high-hazard separations, vault rooms | 3- or 4-hour rated wall |
A general rule in the building code: the door's fire rating should be at least 75% of the wall's fire-resistance rating. A 2-hour fire wall requires a minimum 90-minute rated door assembly.
Steel is the only door material that can reliably achieve a 3-hour fire rating. Wood doors typically max out at 90 minutes, and fiberglass doors rarely exceed 20 minutes. This makes steel fire doors the required choice for the most demanding fire separation applications.
A Note on International Standards
The fire ratings we've discussed aren't just local rules; they are based on strict international standards that ensure consistent safety and performance. To earn a rating, a complete door assembly—including the door, frame, and all hardware—must pass a grueling fire test, like the one specified by ANSI/UL 10C. During this test, the door is subjected to intense furnace heat to prove it can maintain its structural integrity for its rated time. This is why the certification label from a recognized testing lab like UL (Underwriters Laboratories) is so critical. Without that official label, a door is not legally considered one of the certified fire-rated steel doors, no matter how strong it seems. These standards, including NFPA 80 and the International Building Code (IBC), govern everything from manufacturing to installation, ensuring every component works together to protect lives.
UL Certification: Your Proof of Fire Protection
The UL label on a fire rated steel door is not a marketing badge. It is the traceable record of a tested assembly. Understanding what to look for on that label can save you from inspection failures and compliance violations.
What the UL Label Tells You
Every certified fire rated door carries a label on the hinge-side edge that includes:
- Fire rating in minutes or hours
- Manufacturer name or UL file reference number
- Control/serial number for traceability
- Assembly designation (single swing, pair, etc.)
- Temperature rise rating (if applicable: 250°F or 450°F at 30 minutes)
- Smoke and draft control (S label) if tested per UL 1784
Why the Entire Door Assembly Needs a Rating
UL does not certify individual door slabs. It certifies the complete assembly: door, frame, glazing, and hardware working together. If any component is substituted with a non-listed part, the certification is void. This means:
- The frame must be labeled with a matching or higher fire rating
- All hardware (hinges, closers, latches, panic devices) must be fire rated
- Intumescent seals and gaskets must be listed for the assembly
- Any glazing must be fire-protection rated and tested as part of the assembly
Beyond the Flames: Understanding Temperature Rise
Some applications require temperature rise doors that limit heat transfer through the door surface. These are rated at either 250°F or 450°F maximum rise at 30 minutes of exposure:
- 250°F rise: Required for stairwell doors and exit enclosures where occupants may touch the door during evacuation
- 450°F rise: Acceptable for corridors and other locations with less direct occupant contact

Understanding Glass and Glazing in Fire Doors
Many building managers and property owners want the visibility and light that glass provides, but assume it's not possible with a fire-rated door. The good news is that you can have both safety and visibility. Adding a window, or what's known in the industry as a "vision lite," to a fire door is common, but it requires specialized materials and expert installation. Simply cutting a hole and inserting a standard pane of glass creates a dangerous weak point that completely negates the door's fire-resistant capabilities and violates building codes.
Why Standard Glass Fails in a Fire
When exposed to the intense heat of a fire, standard window glass shatters in as little as two to five minutes. This rapid failure is caused by thermal shock. The side of the glass facing the fire expands quickly from the heat, while the other side remains relatively cool. This difference in temperature creates immense stress within the pane, causing it to break apart. Once the glass is gone, the opening allows flames, smoke, and toxic gases to pour through, compromising the entire fire barrier and accelerating the spread of fire throughout the building. This is why using anything other than certified, fire-rated glass is not only a code violation but a serious life-safety hazard.
Types of Fire-Rated Glass
Fire-rated glass is an engineered product designed to withstand extreme temperatures and maintain its integrity during a fire. There are two primary categories you should know. The first is fire-protective glass, such as traditional wired glass or modern ceramics, which blocks flames and smoke but does not stop radiant heat from passing through. The second, more advanced category is fire-resistive glass. This is typically a multi-layered product that not only contains flames and smoke but also acts as an insulating barrier, significantly limiting the transfer of dangerous radiant heat. This type is essential for larger glass installations and in critical egress paths like stairwells, where radiant heat could block a safe exit.
Proper Glazing Installation
Installing glass in a fire door is about more than just the glass itself; it's about the entire glazing system. Using the wrong type of glass or an improper installation method will instantly void the door's UL certification and lead to a failed inspection. The vision lite kit, which includes the metal frame that holds the glass, and the glazing compound or tape used to seal it must also be fire-rated and listed for use with that specific door assembly. This is not a DIY project. A certified professional ensures every component is correct, properly installed, and compliant with all NFPA 80 and local NYC codes. For any door replacement and repair services involving fire-rated components, always rely on experienced technicians to protect your property and your legal obligations.
Steel vs. Wood vs. Fiberglass: Why Steel Wins for Fire Safety
When comparing door materials for fire rated applications, steel holds decisive advantages:
| Feature | Steel | Wood | Fiberglass |
|---|---|---|---|
| Maximum fire rating | 3 hours (180 min) | 90 minutes | 20 minutes |
| Impact resistance | Excellent | Moderate | Poor |
| Moisture resistance | High (Galvanneal) | Low (warps, rots) | Moderate |
| Maintenance | Minimal | Regular (refinishing, swelling) | Moderate |
| Lifespan | 30+ years | 10-20 years | 10-15 years |
| Cost over lifecycle | Lowest | Medium | Highest (replacements) |
| Security | Highest | Low | Very low |
For any application requiring 60 minutes or higher fire protection, steel is the only practical choice. In NYC buildings, where fire codes are among the strictest in the country, fire rated steel doors are the standard for stairwells, exit corridors, apartment entries, and all high-occupancy separations.
The Added Benefit of Sound Reduction
While their primary job is to stop fire, the construction of fire-rated steel doors offers a fantastic secondary benefit: sound reduction. The same core materials that provide insulation and fire resistance—like polystyrene or honeycomb—also work to dampen sound. This is because the dense, insulated core between the two steel panels absorbs sound waves, preventing noise from traveling from one space to another. This makes them an excellent choice for environments where noise control is crucial, such as in busy apartment buildings, quiet hospital corridors, or focused classroom settings. You're not just installing a safety feature; you're also creating a more peaceful and private environment for occupants.
Fire Doors in NYC: What the Building Code Requires
New York City enforces fire door requirements through the 2022 NYC Fire Code, NYC Building Code, and FDNY regulations. Property owners and managers must understand where fire rated doors are legally required.
Where Fire Rated Doors Are Mandatory in NYC
- Stairwell enclosures: Typically 90-minute rated assemblies
- Elevator lobbies: Rating determined by building code analysis
- Apartment entry doors in multi-unit residential buildings
- Corridor doors in hospitals, schools, hotels, and offices (20-45 minute rating)
- Emergency exits and egress paths: 60 to 90-minute rating
- Mechanical and electrical rooms: Rating varies by code
- Fire walls and fire barriers: Up to 3-hour rated assemblies
When Are Exterior Doors Rated?
It’s a common point of confusion: if a door leads outside, does it need a fire rating? In NYC, the answer is often yes. The NYC Building Code requires exterior doors to be fire-rated when they are close to a property line or an adjacent building. This rule is designed to prevent a fire from spreading between structures. An exterior door in these locations has to pull double duty—it must withstand the weather while also meeting strict fire safety laws. This is where a door like a polystyrene-filled steel door is an ideal fit. It provides the thermal insulation necessary for an exterior opening and can be built to achieve the required fire rating, ensuring you meet code without sacrificing energy efficiency.
Self-Closing Doors: What NYC Local Laws 62 & 63 Mean
NYC Local Laws 62 and 63 mandate that fire doors in residential buildings must be self-closing. This means every fire rated door must have a functioning door closer or spring hinge system that returns the door to the fully closed and latched position automatically. Doors propped open, doors with disabled closers, or doors with broken latches are violations that carry fines up to $250 per day.
NFPA 80: Your Guide to Fire Door Inspections
NFPA 80 requires annual inspections of all fire door assemblies. Inspectors check:
- Door closes and latches fully without assistance
- No visible damage to the door, frame, or seals
- Certification labels are legible and present
- Gaps between door and frame meet clearance standards (max 1/8" at jambs and head, 3/4" at bottom)
- All hardware is operational and fire rated
Failing a fire door inspection can result in violations, fines, and increased liability. Working with a certified manufacturer and installer ensures your doors are compliant from day one.
The Role of the Authority Having Jurisdiction (AHJ)
While national standards like NFPA 80 provide the playbook, the local fire safety authority—known as the Authority Having Jurisdiction (AHJ)—is the ultimate referee. In New York City, the AHJ is typically the FDNY or the Department of Buildings. These are the officials who conduct inspections and have the final say on whether your door assemblies meet code. Their interpretation of the rules is the one that matters when it comes to passing an inspection or receiving a violation. This is why working with a team that has deep experience with NYC's specific requirements is so important; they understand not just the codebook, but how the code is enforced on the ground, ensuring your fire-rated doors are compliant from the start.
A Fire Door is Part of a Complete Safety System
It’s crucial to remember that a fire rating applies to the entire opening assembly, not just the door slab. The door, frame, hinges, latching hardware, and closer must all be fire-rated and listed to work together as a single, cohesive system. If you replace a certified closer with a non-rated one or use the wrong type of screws on a hinge, the entire assembly's certification is voided. This is a common reason for failed inspections. A fire door is only as strong as its weakest component, which is why you can't simply swap out parts. True compliance requires a holistic approach, ensuring every piece of the puzzle is correct and certified for the specific door replacement or repair.
When to Call a Professional
Given the complexity of the codes, the strictness of the AHJ, and the fact that the entire door assembly must be certified, it's clear that this isn't a DIY project. If you have any doubt about whether a door needs to be fire-rated, what that rating should be, or if a repair will maintain compliance, it's time to call an expert. A professional assessment is not an admission of defeat; it's a smart business decision that protects your property, ensures tenant safety, and saves you from costly fines and failed inspections. Our OSHA-certified crews specialize in navigating these exact challenges. We can help you understand your obligations and ensure every fire door in your building is safe, compliant, and ready for its next inspection. Don't guess—request a free estimate and get a definitive answer.
Our Process: Crafting Your Custom Fire Rated Steel Door
Most door companies in NYC are installation-only businesses. They order from outside suppliers, mark up the price, and pass along 2-3 week lead times. Universal Fireproof Door operates differently.
We are a vertically integrated manufacturer-installer. Our Brooklyn facility handles design, fabrication, delivery, and professional installation under one roof. This means:
- 3-5 business day standard lead times (industry average: 2-3 weeks)
- 1-3 business day expedited production available
- No minimum order: one door or 100+
- Custom dimensions: non-standard sizes, oversized openings, and specialty configurations
- Full fire rating range: 20, 45, 60, 90, and 180-minute assemblies
- All construction types: hollow metal, steel-stiffened, polystyrene, honeycomb core, and stainless steel
Our Certifications and Experience
- SDI (Steel Door Institute) Registered Manufacturer: the industry's highest manufacturing standard
- Fully Licensed & Insured in New York State
- OSHA-Certified Installation Crews: every technician is safety-trained
- MBE (Minority Business Enterprise) Certified: qualifying for government and corporate diversity contracts
- American-Made Steel: locally sourced, domestically manufactured
- Manufacturing since 1924: over 100 years of fire door expertise
We have secured hospitals, government buildings, airports, schools, hotels, and residential buildings across all five NYC boroughs. View our past projects to see our work.
FAQ: Fire Rated Steel Door Specifications
When Is a Steel Door Officially "Fire Rated"?
Not automatically. A steel door is only fire rated if it has been tested and certified as a complete assembly (door, frame, and hardware) by a recognized testing laboratory like UL or WHI. The certification label on the hinge edge is the proof. A standard steel door without this certification does not qualify as fire rated under building codes.
So, Are All Steel Doors Fire Rated?
No. Many steel doors are manufactured for general security, weather protection, or aesthetic purposes without undergoing fire testing. Only steel doors that carry a UL, WHI, or equivalent certification label with a specific fire rating (20, 45, 60, 90, or 180 minutes) are fire rated. Always verify the label before installation.
What's the Right Steel Gauge for a Fire Door?
Most commercial fire rated steel doors use 18-gauge Galvanneal steel (0.042" thick). For higher security or impact resistance, 16-gauge (0.053") steel is used. The Steel Door Institute (SDI) sets the manufacturing standards for each gauge level.
What's the Lifespan of a Fire Rated Steel Door?
With proper maintenance, a fire rated steel door can last 30 years or more. Steel does not warp, rot, or crack like wood. Annual inspections per NFPA 80 and periodic hardware maintenance extend the service life significantly. If your door needs attention, our fire door repair services can restore compliance without full replacement.
What's the Highest Possible Fire Rating for a Steel Door?
Steel doors can achieve up to a 3-hour (180-minute) fire rating, the highest available for any door material. Wood doors max out at 90 minutes, and fiberglass rarely exceeds 20 minutes. This makes steel the only option for fire wall openings and high-hazard separations.
How Much Does a Fire Rated Steel Door Cost?
Pricing varies based on fire rating, gauge, construction type, hardware, and custom dimensions. A basic fire rated hollow metal door may start around $350, while a 3-hour rated assembly with specialized hardware will cost more. Contact us for a free estimate tailored to your specific project requirements.
Key Takeaways
- Certification is everything: A steel door is only considered fire rated if it has a certification label from a recognized lab like UL. This label proves the entire assembly (door, frame, and hardware) has passed standardized fire testing.
- Construction matches the need: The door's internal core (like polystyrene or steel stiffeners) and steel gauge dictate its performance. These factors affect insulation, impact resistance, and security, so you can choose the right door for a specific location.
- A fire door is a complete system: For a fire rating to be valid, every single component, from the hinges and latches to the glass and seals, must also be fire-rated and installed correctly. In NYC, these doors must also be self-closing to comply with local laws.
Related Articles
Ready to Get Started?
NYC's trusted commercial fire door specialists — fast response, code-compliant work.
What NYC Property Owners Say
UFD replaced 40 fire doors in our office tower on schedule. Their team knew every code requirement and coordinated around our tenants seamlessly.
— Robert M. — Property Manager, Midtown Manhattan
Called them for an emergency repair after a failed inspection. They were on-site within hours and got us back to compliance the same day.
— Angela T. — Facilities Director, Brooklyn Medical
Transparent pricing, expert crew, and the documentation they provided for our building file was perfect. Best contractor experience in NYC.
— James W. — Building Owner, Queens
Frequently Asked Questions
What Makes a Steel Door Fire Rated?
Not every steel door qualifies as fire rated. The critical distinction is certification. A fire rated steel door has been tested as a complete assembly, door, frame, and hardware, under controlled fur…
Inside a Fire Rated Steel Door: Construction Types
Fire rated steel doors are manufactured using several construction methods, each suited to different performance requirements. Universal Fireproof Door manufactures all of the following types in our B…
Steel Gauge Explained: What the Numbers Really Mean
The gauge of the steel used in a fire rated door directly affects its strength, weight, durability, and fire performance. Lower gauge numbers indicate thicker, heavier steel.
Essential Hardware and Components for Fire Doors
A fire door’s rating isn’t just about the door itself; it’s about the entire assembly working in perfect harmony. The frame, hinges, latches, and seals are all critical components that must be r…
Decoding Fire Ratings: From 20 Minutes to 3 Hours
Fire ratings indicate how long the door assembly can withstand fire exposure during standardized testing. The rating applies to the entire assembly, not just the door leaf.
Emergency Fire Door Service — NYC 24/7
Failed inspection? Damaged door? We respond across all five boroughs.
📞 Call (718) 455-8442Need fire door help in NYC?
We manufacture & install in 3–5 days. Violations, replacements & inspections across all 5 boroughs.
Get a Free Estimate →📞 (718) 455-8442Mon–Fri 8AM–4:30PM · No obligationWhy Universal Fireproof Door
- ✓ Manufacturing in Brooklyn since 1924
- ✓ UL Listed & NYC MEA Approved
- ✓ Our own crews — no subcontractors
- ✓ Serving all 5 NYC boroughs & Long Island