A lead-lined door isn't just an access point—it's a critical piece of a room's radiation shielding. Getting it wrong can derail your entire project. If the door, frame, hardware, and fire rating aren't perfectly coordinated, you risk failed inspections, costly change orders, and an opening that simply doesn't perform. This guide breaks down the essential lead-lined door requirements. We'll help you get every detail right from the start, ensuring your space is safe and your project stays on track.
Need a project-specific door quote for a healthcare or laboratory opening? Contact Universal Fire Doors with your drawings, schedules, and shielding notes so our team can review the door and frame requirements.
For general contractors, architects, facility managers, and healthcare owners, the most common mistakes happen before the door is ordered. A shielding report may call for a specific lead equivalency, but the door schedule may not clearly show how that requirement affects the frame, lite kit, closer reinforcement, lock prep, or fire label. When those details are missed, the project can face change orders, delayed inspections, or a door opening that does not perform as intended.
This guide explains when lead-lined doors are commonly required, how radiation shielding specifications work, and what project teams should coordinate before fabrication and installation.
What's the Purpose of a Lead-Lined Door?
Lead-lined doors are commercial door assemblies built with a sheet of lead inside the door construction. The lead acts as radiation shielding. The required thickness is normally stated as lead equivalency, such as 1/32 inch, 1/16 inch, 1/8 inch, or another project-specific value. The right value depends on the equipment in the room, the expected radiation output, the distance to surrounding occupied spaces, wall construction, and the shielding design prepared for the facility.
A lead-lined door is only one part of the protected opening. The frame, glazing, hardware penetrations, thresholds, seals, and installation conditions must also support the shielding design. A standard hollow metal door can provide fire resistance, durability, security, and code-compliant egress, but it does not automatically provide radiation protection unless the assembly is specified and built for that purpose.
Because these openings often appear in medical and research environments, they also need to meet the same practical requirements as other institutional doors: smooth traffic flow, reliable closing, cleanable surfaces, access control compatibility, and durability under frequent use. Universal Fire Doors works with commercial and institutional projects throughout New York City that require careful door and frame coordination, including hollow metal doors, hollow metal frames, fire-rated assemblies, and hardware packages.
Where Are Lead-Lined Doors a Must-Have?
Lead-lined doors are typically required when a door opening falls within the radiation shielding boundary of a room. The exact requirement should come from the project drawings, a shielding report, or a qualified radiation shielding professional. Common locations include:
- X-ray rooms in hospitals, urgent care centers, orthopedic practices, and dental facilities.
- CT scanner suites and imaging corridors where radiation shielding continues around the room perimeter.
- Fluoroscopy rooms, interventional radiology suites, and cath lab support spaces.
- Radiation therapy support areas when the shielding design calls for protected doors or controlled access.
- Veterinary imaging rooms that use diagnostic radiography equipment.
- Research laboratories, testing spaces, or industrial inspection rooms using equipment that produces ionizing radiation.
Not every door near imaging equipment needs lead lining. Some rooms are designed so the shielded wall areas do not include a particular opening, or the door may be positioned outside the controlled boundary. That is why the door supplier should not guess. The project team should confirm the lead equivalency, opening size, handing, frame type, fire rating, and hardware requirements from the approved construction documents.
Who's in Charge of Shielding Requirements?
The lead thickness is not selected by preference. It is normally calculated during the design phase by a medical physicist, radiation safety officer, shielding consultant, architect, or engineering team. Their work considers the type of imaging equipment, workload, room layout, adjacent spaces, distance, barriers, and occupancy. The result is translated into construction requirements for walls, doors, frames, windows, and penetrations.
For door coordination, the important question is simple: what does the approved shielding design require at this opening? Project teams should look for notes such as:
- Required lead equivalency for the door leaf.
- Required lead equivalency for the frame or frame returns.
- Whether the door needs a lead-lined vision panel.
- Whether the opening has a fire rating, smoke requirement, or temperature-rise requirement.
- Door size, thickness, gauge, core, edge construction, and label requirements.
- Hardware set, access control devices, operators, closers, hinges, protection plates, and seals.
If the drawings do not clearly answer these questions, request clarification before ordering. A lead-lined opening is difficult to correct after the door is fabricated, delivered, and installed.
Adhering to Governing Specifications
When it comes to lead-lined doors, following the governing specifications isn't just a good idea—it's essential for safety and compliance. These specialized doors are critical components in the radiation shielding of healthcare and laboratory environments. They are constructed with a specific thickness of lead sheeting, often noted as an equivalency like 1/32 or 1/16 inch, which is determined by a physicist or shielding expert based on the room's equipment and use. It's crucial to remember that the door is just one piece of the puzzle. The frame, any vision panels, and even the hardware must all work together to create a fully protected opening. Simply using a standard commercial door won't provide the necessary radiation protection unless it's been specifically designed and constructed for that purpose.
What Shielding Levels Mean for Your Door's Construction
The most visible part of the assembly is the door leaf, but the shielding requirement changes more than the core. Lead adds weight, affects hardware selection, and can influence how the door is reinforced. The thicker the lead, the heavier the door becomes. That added weight can affect hinge type, closer size, frame anchoring, and installation labor.
Commercial and institutional facilities also need doors that stand up to carts, stretchers, equipment movement, and daily use. In high-traffic healthcare corridors, a door that technically meets a shielding note but is underbuilt for the environment can become a maintenance problem. The project should account for gauge, reinforcement, edge construction, protection plates, and hardware durability.
For many healthcare projects, the door schedule will combine radiation shielding with familiar commercial requirements, such as a 1-3/4 inch thick door, a hollow metal frame, commercial hinges, a lever set or access control lock, a closer, and possibly armor plates. Universal Fire Doors manufactures and supplies custom commercial steel door solutions, including fire-rated steel doors and institutional openings that need precise sizing, hardware preparation, and field coordination.
Core Materials and Construction
At its heart, a lead-lined door is a specialized commercial door with a continuous sheet of lead built right into its core. This lead layer is the key component that provides radiation shielding. The specific thickness of the lead is determined by a project's shielding report and is expressed as "lead equivalency," with common values like 1/32, 1/16, or 1/8 of an inch. While the lead does the heavy lifting for protection, the door itself is typically a commercial hollow metal door, ensuring it also provides the durability and security expected in a high-use environment. The entire assembly, including the door, frame, and any vision panels, must work together to create an effective barrier against radiation.
How Lead Thickness Affects Door Weight and Size
It's a simple equation: the thicker the lead, the heavier the door. This added weight is a critical factor that impacts the entire door opening. A standard door frame or set of hinges might not be sufficient to support a heavy, lead-lined door over thousands of opening and closing cycles. That's why the specification is so important. The increased weight will influence the type of hinges required, the size of the door closer, the strength of the frame anchoring, and even the labor needed for a safe installation. Getting these details right from the start prevents future hardware failure and ensures the door operates smoothly and safely for years to come.
Aesthetic and Protective Finishes
Just because a door serves a highly technical purpose doesn't mean it has to look out of place. Lead-lined doors are frequently installed in modern healthcare and research facilities, so they need to meet the same practical and aesthetic standards as any other institutional door. This means ensuring smooth traffic flow, providing easily cleanable surfaces, and integrating with access control systems. These doors can be finished to match your facility's design while still offering incredible durability. Whether it's for a busy hospital corridor or a sterile laboratory, the final product is a door that is both protective and perfectly suited to its environment.
Don't Forget the Frame: A Key Part of Shielding
A lead-lined door will not protect the opening properly if the frame condition leaves an unshielded gap. The frame may need lead lining, lead wrapped returns, special anchors, or coordination with lead-lined walls. The exact detail depends on the wall type, the shielding report, and how the frame is installed into the construction.
Frame coordination is especially important in renovation work. Existing masonry, drywall, or hospital corridor conditions may limit how the frame can be removed and replaced. If the project requires a new lead-lined frame, the team needs to plan for demolition, wall repair, anchoring, firestopping, and inspection access. If the frame stays in place, the project team must confirm whether that existing condition can meet the shielding requirement.
Contractors should also review throat size, jamb depth, welded versus knock-down construction, anchor type, floor conditions, and wall lead termination. A clean frame detail helps the installer maintain alignment, closer performance, latch engagement, and the intended protection at the perimeter of the opening.
Ensuring a Seamless Shield with Wall Overlap
To create a complete radiation barrier, the lead in the door frame must overlap with the lead in the surrounding walls. Think of it like this: even the best lead-lined door is ineffective if there are gaps around the edges where radiation can leak through. The specific way this overlap is achieved depends heavily on the wall construction—whether it's drywall, masonry, or another material—and the details laid out in your project's shielding report. This is especially critical in renovation projects where existing conditions can make a seamless integration more complex. Proper planning for wall repairs, anchoring, and firestopping is essential for any door replacement or repair involving radiation shielding, ensuring the entire opening provides the intended protection.
Adding Vision Panels: What to Know About Lead Glass
Vision panels are common in healthcare, laboratory, and institutional doors because staff need visibility without opening the room. In a lead-lined door, a standard glass lite is not enough. The glazing must match the shielding design, usually through lead glass or another approved radiation shielding glazing product. The lite kit, glazing bead, and cutout must be coordinated so the protected area is not compromised.
Adding a vision panel also affects other requirements. The size and location may be limited by fire rating rules, accessibility requirements, room function, security concerns, or the shielding design. If the door must carry a fire label, the glazing and lite kit must be compatible with that label. If the room needs patient privacy or equipment control, the vision panel may need blinds, films, or a smaller protected opening.
Do not assume that a vision panel shown in the architectural elevation automatically satisfies the shielding note. Confirm the lead glass thickness, frame kit, fire rating compatibility, and final clear view area before fabrication.
Sizing and Placement Rules
Deciding where to put a vision panel and how big it should be isn't a matter of preference. The size and location are strictly governed by the door's specific function and a handful of critical regulations. Fire rating rules, for example, place firm limits on the maximum size of any glass cutout to ensure the door maintains its integrity in a fire. Accessibility requirements also play a role, dictating placement so that people in wheelchairs have a clear line of sight. Most importantly, the shielding design itself will constrain the vision panel's dimensions to ensure there are no weak spots in the radiation barrier. For facilities like hospitals or labs, these rules ensure the door is safe, functional, and fully compliant.
The Importance of Impact-Resistant Safety Glazing
The glass inside a lead-lined vision panel does more than just provide a view; it's an active part of the room's shielding system. Because of this, you can't use standard glass. The glazing must offer the same level of radiation protection as the door itself, which almost always requires installing lead glass with a specific lead equivalency. Furthermore, in busy environments where carts, gurneys, and equipment are constantly on the move, this glass must also be impact-resistant. Safety glazing prevents shattering, which is a critical feature for avoiding injuries and maintaining a safe operational environment. This is another essential detail to coordinate, especially when dealing with fire-rated doors that already have stringent material and construction requirements.
Getting the Hardware Right for Heavy Shielded Doors
Lead-lined doors are heavier than standard doors, so hardware cannot be treated as an afterthought. The door must open, close, latch, and remain aligned through repeated use. In healthcare settings, that performance is not just convenient. It supports life safety, infection control, security, and daily operations.
Key hardware items to coordinate include:
- Hinges or pivots: Use hardware appropriate for the door weight, width, usage level, and label requirements.
- Closers: Select a closer that can control the heavier leaf without making the door difficult to open.
- Locks and access control: Coordinate electric strikes, card readers, maglocks, electrified hinges, and wire transfers with shielding and fire code requirements.
- Panic hardware: Required egress hardware must be compatible with door construction, fire rating, and opening function.
- Protection plates: Kick plates, armor plates, and stretcher plates can protect high-use doors in medical corridors.
- Seals and thresholds: Perimeter details may affect smoke control, acoustics, air movement, and the finished shielding condition.
Universal Fire Doors supplies commercial door hardware and coordinates custom prep for commercial openings, which is especially important when a project combines shielding, access control, and code-compliant egress.
Planning a hospital, imaging center, or laboratory renovation in NYC? Review our commercial door services and send your door schedule before fabrication begins.
Hardware Compatibility and Restrictions
Because lead-lined doors are significantly heavier than their standard counterparts, you can't just use off-the-shelf hardware. The right components are essential for ensuring the door opens smoothly, closes securely, and stays perfectly aligned over thousands of cycles. In a busy hospital or lab, this isn't just a matter of convenience—it's a critical part of safety, security, and daily workflow. For instance, hinges must be rated for the door's specific weight, and the closer needs enough power to control the heavy leaf without making it a struggle to open. Choosing the right commercial door hardware also means coordinating locks, exit devices, and any access control systems to work seamlessly with the door's construction and shielding, ensuring no weak points are created in the protective barrier.
Ensuring Smooth Operation with a Leading Edge
A lead-lined door is only effective if the entire opening is shielded, and that includes the frame. If there's a gap between the door and the frame, or the frame and the wall, radiation can pass through, creating an unshielded weak point. To prevent this, the frame itself often needs to be lead-lined or have lead-wrapped returns that overlap with the lead in the wall. This creates a continuous protective barrier, a core principle that also applies to any fire-rated door installation. This detail is especially crucial during renovations, where existing wall conditions can make it challenging to install a new, properly shielded frame. Planning for how the frame will anchor into the wall and integrate with existing construction is a step that can't be overlooked for a successful and safe installation.
Balancing Fire Safety, Egress, and Radiation Shielding
Many lead-lined openings also sit in rated corridors, suite separations, stair access paths, or other code-regulated locations. When that happens, the door assembly may need to satisfy both the radiation shielding design and the fire or life safety requirement. One requirement does not cancel the other.
For example, an imaging room door in a healthcare corridor may need lead lining and a labeled fire-rated assembly. A lab opening may need durability, access control, and a closer, while also fitting into a smoke or fire barrier. A treatment area may need a specific swing, clear width, latch function, and signage. Each condition should be reviewed as a complete opening, not as separate parts ordered from different sources.
Universal Fire Doors offers fire ratings from 20 minutes to 3 hours on appropriate steel door assemblies, along with custom frame and hardware coordination. For projects with shielding requirements, the safest approach is to identify the required fire label, shielding value, and hardware set together so the assembly can be quoted and built around the complete specification.
Understanding Fire Rating Limitations
It's important to know that while you can combine radiation shielding with fire protection, there are specific limits. For instance, a lead-lined door typically can't achieve a fire rating higher than 45 minutes. There are also size constraints to consider; a single 45-minute rated lead-lined door usually can't be larger than 4 feet wide by 8 feet tall. These aren't just minor details—they can significantly impact your design and compliance strategy. When your project requires both, you have to satisfy the shielding design and the life safety code. One doesn't override the other. This is why it's so critical to treat the opening as a complete system, ensuring the door, frame, and hardware all work together to meet every requirement. Properly specifying fire-rated doors with these added complexities is key to avoiding costly mistakes and delays during inspection.
Installing Lead-Lined Doors Without Disrupting Operations
Even the right door can fail the project if installation is poorly coordinated. Healthcare and laboratory buildings often have active operations, infection control requirements, security rules, controlled corridors, and limited work windows. Lead-lined doors can also require extra handling because of their weight and the need to protect the frame, wall returns, and finished surfaces.
Before installation, project teams should confirm:
- Final field measurements, including wall thickness and floor conditions.
- Approved door handing, swing, and hardware functions.
- Delivery path, elevator access, staging area, and protection requirements.
- Whether temporary barriers, infection control measures, or off-hour work are needed.
- How the frame ties into the lead-lined wall or other shielded construction.
- Inspection timing for fire rating, life safety, and radiation shielding acceptance.
Universal Fire Doors serves Brooklyn, Manhattan, Queens, the Bronx, Staten Island, Long Island, and nearby New Jersey markets with door manufacturing, supply, installation, repair, and project coordination. For active facilities, phased installation and reliable scheduling can make the difference between a smooth turnover and a costly delay.
Your Pre-Order Checklist for Lead-Lined Doors
Use this checklist before issuing a purchase order or approving a submittal:
- Confirm the lead equivalency required for each door opening.
- Confirm whether the frame also needs lead lining or special shielding details.
- Verify door size, thickness, swing, handing, gauge, core, and edge construction.
- Identify the fire rating, smoke requirement, or other label requirement.
- Confirm whether a vision panel is required and whether it needs lead glass.
- Review hardware by opening, including hinges, closers, locks, operators, and access control.
- Check whether added door weight changes hardware, anchoring, or installation requirements.
- Coordinate wall construction, frame anchors, lead returns, and perimeter details.
- Confirm field measurements before fabrication.
- Submit all door, frame, hardware, and glazing details for review before release.
This level of coordination may feel detailed, but it prevents the most common field problems. Shielded openings are not good candidates for last-minute substitutions.
Addressing Gaps at the Door Bottom
A perfectly constructed lead-lined door can still fail if there are unshielded gaps around the perimeter. The space between the bottom of the door and the finished floor is a common weak point that can compromise the entire shielding system. To maintain a continuous barrier, this gap must be addressed. As industry experts suggest, if the undercut is an inch or more, you'll need special lead-lined components like thresholds or automatic door bottoms to block potential radiation leaks. These details should be part of the initial door and hardware specification, not an afterthought. A professional installation ensures that every part of the opening, from the frame to the floor, works together to provide complete protection.
Integrating Safety Interlocks and Warning Lights
In rooms with active X-ray equipment, the door is part of a larger safety system. It’s not enough for the door to simply be present; it needs to interact with the machinery. Safety interlocks are a critical feature, often including a switch that automatically stops the X-ray machine if the door is opened during a procedure. Additionally, a lighted "X-Ray On" sign installed above the door is a non-negotiable visual cue that alerts staff and patients to active radiation. Integrating these features requires careful coordination between the door, frame, hardware, and the facility's electrical systems, a process our team manages for complex hospital door installations.
The Final Step: Post-Installation Radiation Testing
Your responsibility doesn't end once the door is hung. The final, and arguably most important, step is to verify that the shielding works as intended. After the complete door assembly is installed, a qualified radiation physicist or expert must test the room to ensure it meets all safety standards before it can be put into service. This isn't just a formality; it's a critical check to confirm there are no leaks in the shielding envelope. This post-installation testing validates the entire system—from the door and frame to the surrounding walls—and provides the final sign-off that the space is safe for occupancy and ready for clinical or research operations.
Planning Your Purchase: Sizing, Costs, and Timelines
Once you have the technical specifications locked down, it's time to move into the practical side of planning your purchase. Getting the logistics right—from sizing and budget to project timelines—is just as important as getting the lead thickness correct. These details ensure the door not only meets shielding requirements but also fits your space, budget, and construction schedule. Thinking through these factors ahead of time helps prevent costly surprises and keeps your project running smoothly from procurement to final inspection.
Standard and Maximum Door Sizes
Lead-lined doors are available in standard commercial sizes, but their special construction can influence maximum dimensions. For wood doors, you’ll often find that single doors can be manufactured up to 4 feet wide and 8 feet tall, while pairs can reach up to 8 feet wide and 8 feet tall. However, many healthcare and laboratory projects require custom dimensions to accommodate large equipment or match existing openings. For these situations, custom-fabricated steel doors offer more flexibility. Working with a manufacturer that specializes in fire-rated and custom steel doors ensures you can get the precise size you need without compromising on shielding, hardware compatibility, or structural integrity, especially when dealing with the added weight of lead.
Budgeting for Your Door: Costs and Options
The cost of a lead-lined door assembly can vary significantly based on your project's specific needs. While a basic lead-lined door might start around $6,300, this price is just a baseline. The final cost will depend on several key factors: the required lead thickness, the overall size of the door and frame, the fire rating, the hardware package, and the choice between a wood or steel door. Because these are highly specialized products, getting a detailed, project-specific quote is the only way to establish an accurate budget. To get a clear picture of the costs for your facility, it’s best to request an estimate with your complete specifications, including drawings and shielding reports.
Factoring in Lead Times for Custom Orders
Lead-lined doors are not off-the-shelf items; they are custom-fabricated for each project. You should plan for a manufacturing lead time of around four to five weeks. It's important to remember that this timeframe typically begins after your submittals are approved and does not include shipping or installation. For project managers and general contractors, this means building a comfortable buffer into the construction schedule. Ordering well in advance is critical to avoid delaying other trades and final inspections, particularly in active facilities like hospitals where downtime is not an option. Coordinating with your installer early helps ensure that delivery and installation are scheduled efficiently, minimizing disruption to ongoing operations.
Considering Alternatives to Full Door Replacement
In some renovation projects, a full door and frame replacement might not be practical or necessary. Before assuming you need to tear everything out, it’s wise to assess the existing conditions. A licensed medical physicist should always be the one to determine the required level of lead protection for your space. If your existing frame is in good condition and compatible with a new lead-lined door, you may be able to replace only the door leaf. This approach requires careful coordination to ensure the new door fits perfectly and that the entire opening meets the shielding requirements. Consulting with experts in door replacement and repair services can help you determine the most effective and compliant solution for your facility.
Your NYC Partner for Lead-Lined Door Requirements
Universal Fire Doors is a Brooklyn-based commercial door manufacturer and installer serving contractors, property managers, hospitals, schools, laboratories, and institutional facilities across New York City. The company provides custom steel door and frame solutions, fire-rated assemblies, hardware supply, field measurement, installation, repair, and project support.
For lead-lined door projects, our role is to help the project team turn the shielding notes and architectural schedule into a coordinated door opening. That may include reviewing sizes, frames, hardware preps, fire labels, access control needs, installation constraints, and quote details. Because Universal Fire Doors handles custom commercial and institutional door work, we understand how small specification gaps can create major field delays.
Whether the project involves a single imaging suite door or a larger healthcare renovation with multiple rated openings, early review is the best way to keep the job moving.
Send your plans, door schedule, hardware set, and shielding notes to Universal Fire Doors for a custom quote. Start through our contact page or learn more about Universal Fire Doors.
Frequently Asked Questions About Lead-Lined Doors
Do all X-ray rooms need lead-lined doors?
No. The requirement depends on the shielding design for the room. If the door opening is part of the protected barrier, the door may need a specified lead equivalency. If the opening is outside the shielding boundary or protected by another design approach, it may not need lead lining. Always follow the approved shielding report and drawings.
Can a lead-lined door also be fire-rated?
Yes, but the assembly must be specified and supplied to meet both requirements. The door, frame, glazing, hardware, and label conditions must be compatible. Do not assume a standard fire-rated door automatically satisfies radiation shielding requirements.
Does the frame need lead lining too?
Often, yes. If the frame sits within the shielded barrier, the frame and wall returns may need shielding details. The exact requirement should be shown in the shielding design or clarified by the design team.
Can lead-lined doors have windows?
Yes, when the vision panel uses appropriate radiation shielding glazing and a compatible lite kit. The size, location, lead glass thickness, and fire rating compatibility should be confirmed before fabrication.
Why are lead-lined doors heavier than standard doors?
The lead sheet inside the door adds weight. That added weight affects hinge selection, closer sizing, frame anchoring, handling, and long-term maintenance. Hardware should be selected for the actual door weight and usage level.
Ready for a Quote? Here’s What We Need
Provide the door schedule, opening sizes, swings, frame details, lead equivalency, fire rating, vision panel requirements, hardware sets, access control notes, and project location. Drawings and specifications help the door supplier identify conflicts before fabrication.
Key Takeaways
- A lead-lined door is a complete system: Successful radiation shielding depends on more than just the door itself. The frame, hardware, and any vision panels must all be specified together to create a fully protected, functional, and code-compliant opening.
- The shielding report is your single source of truth: The required lead thickness is a precise calculation made by a qualified expert. Always refer to the project's official shielding report to confirm the lead equivalency for the door, frame, and glass before placing an order.
- Heavier doors require heavy-duty planning: The lead inside these doors adds significant weight, which affects hardware selection, frame anchoring, and installation. You must choose hinges, closers, and other components specifically rated for the door's final weight to ensure safe, smooth, and lasting operation.
Related Articles
Ready to Get Started?
NYC's trusted commercial fire door specialists — fast response, code-compliant work.
What NYC Property Owners Say
UFD replaced 40 fire doors in our office tower on schedule. Their team knew every code requirement and coordinated around our tenants seamlessly.
— Robert M. — Property Manager, Midtown Manhattan
Called them for an emergency repair after a failed inspection. They were on-site within hours and got us back to compliance the same day.
— Angela T. — Facilities Director, Brooklyn Medical
Transparent pricing, expert crew, and the documentation they provided for our building file was perfect. Best contractor experience in NYC.
— James W. — Building Owner, Queens
Frequently Asked Questions
What's the Purpose of a Lead-Lined Door?
Lead-lined doors are commercial door assemblies built with a sheet of lead inside the door construction. The lead acts as radiation shielding. The required thickness is normally stated as lead equival…
Where Are Lead-Lined Doors a Must-Have?
Lead-lined doors are typically required when a door opening falls within the radiation shielding boundary of a room. The exact requirement should come from the project drawings, a shielding report, or…
Who's in Charge of Shielding Requirements?
The lead thickness is not selected by preference. It is normally calculated during the design phase by a medical physicist, radiation safety officer, shielding consultant, architect, or engineering te…
What Shielding Levels Mean for Your Door's Construction
The most visible part of the assembly is the door leaf, but the shielding requirement changes more than the core. Lead adds weight, affects hardware selection, and can influence how the door is reinfo…
Don't Forget the Frame: A Key Part of Shielding
A lead-lined door will not protect the opening properly if the frame condition leaves an unshielded gap. The frame may need lead lining, lead wrapped returns, special anchors, or coordination with lea…
Emergency Fire Door Service — NYC 24/7
Failed inspection? Damaged door? We respond across all five boroughs.
📞 Call (718) 455-8442Need fire door help in NYC?
We manufacture & install in 3–5 days. Violations, replacements & inspections across all 5 boroughs.
Get a Free Estimate →📞 (718) 455-8442Mon–Fri 8AM–4:30PM · No obligationWhy Universal Fireproof Door
- ✓ Manufacturing in Brooklyn since 1924
- ✓ UL Listed & NYC MEA Approved
- ✓ Our own crews — no subcontractors
- ✓ Serving all 5 NYC boroughs & Long Island