NYC Egress Door Width: 32 Inches, Except for Beds and Detention

MEA ApprovedUL ListedFDNY CompliantNFPA 80NYC DOBLicensed & Insured
Free Estimates — We Respond in 2 Hours

Get Your Free Same-Day Estimate

Tell us about your building — we manufacture & install in 3–5 days. No middlemen. No delays.

✓No obligation|✓Licensed & Insured|✓FDNY Compliant|✓2-Hour Response|📞 (718) 455-8442

Under the NYC Building Code, an egress door must provide at least 32 inches (812.2 mm) of clear width, measured from the face of the door to the stop with the door open at 90 degrees. Two occupancies use different numbers: 41.5 inches (1054.1 mm) where beds are moved in Group I-2, and 28 inches (711.2 mm) for Group I-3 resident sleeping units.


TL;DR:

  • Measure at 90 degrees with hardware installed; a nominal 36 inch leaf usually clears the required opening, while a 34 inch leaf often does not.
  • For double doors without a center mullion, at least one leaf must provide the full required clear opening; nominal combined width alone does not satisfy the rule.
  • Certain dwelling unit interior doors are exempt, but unit entrances and doors on the exit route remain subject to the general rule.
  • At full opening, a door cannot reduce required width by more than 7 inches; in any position, the reduction cannot exceed half.
  • DOB has historically accepted 30 inch openings in existing multiple dwellings if unaltered and compliant with maneuvering clearances; confirm current approval before relying on the exception.

Universal Fireproof Door
Get Egress Doors Made to Fit
Universal Fireproof Door manufactures and installs fire-rated steel doors and frames for commercial, residential, and industrial properties.

Visit Universal Fireproof Door

Table of Contents

What does the NYC Building Code say about egress door width?

The rule sits in the door size provisions of Chapter 10. Section 1010.1.1 sets the minimum clear opening, the measurement method, exceptions for dwelling units and storage closets, and variations for I-2 and I-3 occupancies.

The baseline: 32 inches (812.2 mm) of clear width, measured between the face of the door and the stop with the door open at 90 degrees. That is the figure inspectors check first, and it is clear width, not the nominal size stamped on the door.

A few related limits matter when you write a spec or review shop drawings:

  • Maximum leaf width: a swinging door leaf is subject to a nominal width limit.
  • Double doors: when an opening has two leaves and no central mullion, at least one leaf must deliver the full 32 inches of clear width.
  • Common exceptions: interior egress doors inside R-2 and R-3 dwelling units, storage closets under 10 square feet, and revolving doors follow their own provisions.

A standard 36-inch door leaf usually clears 32 inches once the thickness of the door and the stop are taken out. A 34-inch leaf often does not, which is why nominal sizes are a poor shortcut.

Which occupancies use a different minimum?

Most buildings use the 32-inch baseline, but the code carves out two institutional cases under 1010.1.1.1:

  • Group I-2 (hospitals, nursing homes): means-of-egress doors used for moving beds have a separate clear-width requirement. Gurneys and bed frames, not people, determine the relevant clearance.
  • Group I-3 (detention and correctional): doors to resident sleeping units have a separate clear-width requirement.
  • R-2 and R-3 residential: interior doors inside a dwelling unit are among the doors the code excepts from the baseline, as listed in section 1010.1.1. The unit’s entrance door and doors on the path out of the building still follow the general rule.

If you manage a mixed building, apply the number that matches the occupancy of the space the door serves, not the building as a whole.

How do you measure the clear opening?

Measurement mistakes cause more failed inspections than design errors do. Follow this sequence:

  1. Open the door to 90 degrees.
  2. Measure horizontally from the face of the open door leaf to the stop on the latch side.
  3. Record the result in inches and confirm it reaches 32 inches (812.2 mm), or the occupancy figure that applies.
  4. Repeat with the door’s hardware installed, since closers, pulls and thresholds can pinch the usable width.

Projection rules are in Chapter 10 of the 2022 Building Code. A fully opened door cannot reduce the required width by more than 7 inches (177.8 mm), and in any position it cannot reduce it by more than one-half. Surface-mounted latch release hardware can be exempted from the 7-inch limit under specific mounting conditions.

Swing direction changes how much a leaf intrudes into a corridor, a point covered well in this guide on whether doors should swing in or out.

Pro Tip: Measure with the hardware on and the door at a true 90 degrees. A tape held against a half-open leaf will overstate the clear width.

Technician measuring a fully open door

What should renovation teams know before changing a door?

Replacing a door can quietly shrink an approved opening. Thicker leaves, added closers and deeper stops all eat into clear width. Our guide to egress door renovations walks through what to check before demolition.

  • Existing multiple dwellings: DOB has historically accepted an existing masonry bearing-wall opening of at least 30 inches in place of 32 inches, when it is not being enlarged and maneuvering clearances are met, as described in Technical Policy and Procedure Notice #9/88. Confirm current DOB acceptance before relying on it.
  • Approved capacity: never reduce approved egress capacity during an alteration without DOB approval or a variance.
  • Obstructions: the FDNY Fire Code egress chapter requires egress paths to stay free of obstructions at all times. Stored furniture, carts and stock that narrow a path are a frequent source of violations.
  • Quick fix: clear the path, photograph it, and re-measure the opening before the re-inspection.

For tenant buildouts, see our notes on fire door compliance for contractors.

Why does factory-direct manufacturing lower code risk?

Most width failures start in the field, when a door that was ordered by nominal size arrives and does not clear 32 inches. Because we build our doors and frames ourselves and install them ourselves, the person who measures the opening is the person who specifies the door and signs off the install. That cuts the handoffs where clear width gets lost. It also shortens lead times and reduces rework on site. If you want a second set of eyes on an opening, ask us for an on-site inspection or estimate.

— Esteban

How we help you meet egress door requirements in NYC

We manufacture, install, repair and inspect doors for NYC buildings, and we can help you hit the right clear width the first time:

  • Custom door and frame manufacturing sized to your opening on our commercial doors page
  • Fire door installation, replacement and repair through our services team
  • Fire door inspections to verify clear width and hardware before DOB or FDNY does
  • Violation removal when an inspection has already flagged a door

Request a site estimate or schedule an inspection, and we will confirm what your openings need.

Universal Fireproof Door

FAQ

What is the minimum width of an egress door in NYC?

The minimum clear width is 32 inches (812.2 mm), measured between the face of the door and the stop with the door open at 90 degrees, per section 1010.1.1.1. Group I-2 occupancy doors that move beds require 41.5 inches, and Group I-3 resident sleeping unit doors require 28 inches.

What does the NYC fire code say about egress?

The Fire Code requires means of egress to be maintained free from obstructions at all times. Furniture, storage or equipment that narrows a required path is a common reason for violations, as outlined in the FDNY egress chapter.

Can a bedroom door be 28 inches wide?

Interior doors inside R-2 and R-3 dwelling units are among those the code excepts from the 32-inch baseline, according to section 1010.1.1. The 28-inch figure in the code applies specifically to Group I-3 resident sleeping units, so check your occupancy before assuming it fits.

Does door hardware affect egress width?

Yes. Hardware and projections can reduce effective clear width, and a fully open door cannot cut the required width by more than 7 inches, per Chapter 10. Measure with hardware installed.

Sources

Free Estimates · 2-Hour Response

Need fire door help in NYC?

We manufacture & install in 3–5 days. Violations, replacements & inspections across all 5 boroughs.

Get a Free Estimate →📞 (718) 455-8442Mon–Fri 8AM–4:30PM · No obligation

Why Universal Fireproof Door

  • ✓ Manufacturing in Brooklyn since 1924
  • ✓ UL Listed & NYC MEA Approved
  • ✓ Our own crews — no subcontractors
  • ✓ Serving all 5 NYC boroughs & Long Island

Related Articles

NYC Egress Door Width: 32 Inches, Except for Beds and Detention

Leave a Reply

Your email address will not be published. Required fields are marked *

NYC Egress Door Width: 32 Inches, Except for Beds and Detention

Leave a Reply

Your email address will not be published. Required fields are marked *