What Is a Temperature Rise Door? A Guide for NYC
You’re likely familiar with fire doors and their time ratings—20, 45, or 90 minutes. But what happens when your building permit or fire code calls for a temperature rise door? …
Get a Free Fire Door Quote for Your NYC Property
Fill out the form below or call us at (718) 455-8442 — we respond fast.
You’re likely familiar with fire doors and their time ratings—20, 45, or 90 minutes. But what happens when your building permit or fire code calls for a temperature rise door? This is a separate, critical requirement that goes beyond just stopping flames. Think about it: a standard fire door can get incredibly hot during a fire, radiating enough heat to make an escape route impassable. A temperature rise door is engineered to solve this exact problem by insulating against that heat. Getting this detail wrong isn't just a paperwork issue; it means failed inspections, costly violations, and a real safety risk during an evacuation.
Need custom temperature rise doors for your NYC building project? Call Universal Fire Doors at (718) 455-8442 or request a free estimate. We manufacture 250F, 450F, and 650F temperature-rise core doors in our Brooklyn facility with 3-5 business day turnaround.
This guide covers what temperature rise ratings mean, how the three ratings differ from each other and from standard fire ratings, and exactly where NYC building code requires them -- with a comparison table by application.
What Is a Temperature Rise Door?
A temperature rise door is a fire-rated door assembly that must also limit the heat transmitted through the door to the unexposed (egress) side. Standard fire-rated doors are tested and rated only for how long they resist fire and smoke penetration. A temperature rise door must pass that same fire test AND meet a maximum temperature limit on the side occupants may touch or pass during evacuation.
NFPA 80 and IBC (International Building Code) define temperature rise in terms of the maximum temperature increase on the unexposed face of the door at 30 minutes into the fire test. The three ratings in common use are:
- 250F temperature rise -- The unexposed face cannot exceed a 250-degree Fahrenheit rise above ambient at 30 minutes
- 450F temperature rise -- The unexposed face cannot exceed a 450-degree Fahrenheit rise above ambient at 30 minutes
- 650F temperature rise -- The unexposed face cannot exceed a 650-degree Fahrenheit rise above ambient at 30 minutes
Note that these are rises above ambient, not absolute temperatures. At a room temperature of approximately 70F, a 250F rise means the door face cannot exceed about 320F. A 650F rise means the face cannot exceed about 720F.
How They Limit Heat Transfer
A Note on Heat Transfer
Standard fire-rated doors are excellent at their primary job: containing flames and smoke to one area. But imagine a fire raging on one side of a stairwell door. Even if the door holds back the fire, it can get incredibly hot, radiating heat into the stairwell. Temperature rise doors are specifically engineered to solve this problem. They have special core materials that act as an insulator, significantly slowing down how much heat passes through to the non-fire side. This isn't just a minor upgrade; it's a critical safety feature designed to protect people, not just property, during an evacuation.
So, what do those numbers—250°F, 450°F, and 650°F—actually mean? They represent the maximum temperature increase allowed on the cool side of the door during the first 30 minutes of a fire test. For example, a 250°F-rated door won't get more than 250 degrees hotter than the starting room temperature on the side people are using to escape. This rating is a direct measure of the door's insulating power. A lower number means better insulation and a cooler surface, which is vital in high-traffic escape routes where people might brush against the door or where combustible materials could be stored nearby.
The whole point of this technology is to keep escape routes usable during a fire. Think about the critical paths in your building, like stairwells and corridors that lead to an exit. If a fire door in one of these areas becomes red-hot, it can make the entire passageway impassable, trapping people inside. Temperature rise doors ensure these emergency exit routes remain cool enough for occupants to pass by safely, even if a fire is burning just on the other side. This feature is a non-negotiable requirement in specific locations outlined by NYC building codes precisely because it keeps evacuation paths clear and helps prevent panic and injury.
Is a Temperature Rise Rating the Same as a Fire Rating?
A standard fire door carries a time rating: 20, 45, 60, 90, or 180 minutes. That rating tells you how long the assembly resists fire penetration, structural failure, and smoke passage. A 90-minute fire door must hold up for 90 minutes in a standardized furnace test per NFPA 252 or ANSI/UL 10C protocols.
Temperature rise is an additional requirement layered on top of the fire rating for specific locations in a building. A door can be a 90-minute fire door without any temperature rise requirement. A door can also be a 90-minute fire door WITH a 250F temperature rise requirement. Both meet the fire test -- but the second one must also keep the unexposed face below the temperature threshold.
The practical difference is core construction. Standard fire doors often use honeycomb or polystyrene cores. Temperature rise doors require a specially designed thermal core -- typically a mineral-based or heat-resistant material -- that slows heat transfer through the door leaf. That core adds cost and changes the door's weight and overall specification.
Universal Fire Doors manufactures three temperature-rise core options: 250F, 450F, and 650F, available in all standard gauge steel.
Understanding Testing Standards
So, how do officials certify that a door meets these strict heat limits? It all comes down to the testing process. Temperature rise doors are evaluated using the same fire endurance tests as standard fire-rated doors, following protocols like NFPA 252 or UL 10C. This initial test involves placing the door in a large furnace to see how long it can resist fire and smoke penetration. But for a temperature rise rating, the test goes a step further. During the first 30 minutes of that fire test, technicians measure the temperature on the non-fire side of the door. To earn a 250F rating, for example, the door's surface can't increase by more than 250°F above the starting room temperature. This additional requirement ensures the door not only stops flames but also limits the dangerous radiant heat that can make an escape route impassable.
Door Assemblies vs. Walls
You might wonder why a door needs a special temperature rating when it's installed in a fire-rated wall that already blocks heat. It’s a great question, and the answer lies in how different building components are tested. Fire-rated walls are designed to limit heat transfer for their entire rating period (e.g., one or two hours). Doors, however, are tested differently. A standard fire door's main job is to block flames and smoke to maintain the integrity of the fire barrier. The temperature rise requirement essentially brings the door's performance closer to that of the wall for the first 30 minutes of a fire. This is critical for emergency exit doors in stairwells, ensuring the path remains safe for people to touch and pass by during an evacuation.
Breaking Down the 3 Temperature Rise Ratings
Here is how the three ratings differ in terms of what they allow and where they are used:
| Rating | Max Temp Rise at 30 Min | Core Type | Typical Application | Relative Cost |
|---|---|---|---|---|
| 250F | 250 degrees F above ambient | Heavy thermal mineral core | Stairwell egress enclosures (most restrictive code locations) | Highest |
| 450F | 450 degrees F above ambient | Mineral/composite thermal core | Exit corridors, stairwell doors in lower-rise buildings | Mid-range |
| 650F | 650 degrees F above ambient | Insulated thermal core | Exit corridors, 20-minute rated locations with temperature requirements | Lower than 250F and 450F |
A 250F door imposes the strictest heat transmission limit. The lower the number, the tighter the requirement and the more robust the thermal core must be. When specifying temperature rise doors, always confirm the required rating with the project's architect or fire protection engineer -- substituting a 650F door where a 250F is required fails code.
Testing Durations for Higher Fire Ratings
A common question we get is whether the temperature rise test duration changes for doors with higher fire ratings. For instance, does a 3-hour (180-minute) door have its temperature checked later in the test than a 60-minute door? The answer is no. The standard is consistent: the temperature rise on the non-fire side is always measured at the 30-minute mark of the fire test. This is true whether the door has a 60, 90, or 180-minute rating. The goal is to ensure that even early in a fire event, the escape route remains safe from extreme radiant heat, giving occupants a chance to evacuate.
This means a door assembly has to pull double duty. A 90-minute, 250F temperature rise door must not only withstand the full force of the fire test for an hour and a half, but it must also keep its unexposed side from getting too hot within the first 30 minutes. This is why the core material is so critical. While a standard hollow metal door might survive the fire, only one with a specialized mineral core can meet both the time and temperature requirements. Understanding this distinction is key to specifying the correct fire-rated doors for critical locations like stairwells.
Why Do Temperature Rise Requirements Exist?
During a fire, occupants may need to approach a stairwell or corridor door to determine if the path is safe for evacuation. If the door surface is dangerously hot, contact alone can cause injury, and radiant heat near the door can be incapacitating. A high-temperature door face also signals that conditions on the fire side may be unsurvivable.
Temperature rise requirements exist to protect occupants in the seconds before they open an exit door. They are most critical in stairwell enclosures -- the primary evacuation path in high-rise buildings -- where occupants travel past fire doors on every floor. If stairwell doors allow excessive heat transmission, the evacuation path itself can become untenable.
In New York City's high-rise building stock, stairwell enclosures are heavily trafficked during alarm events. Temperature rise requirements are not a specification formality. They are a direct occupant safety measure.
Universal Fire Doors manufactures custom temperature-rise core doors to exact specifications. Call (718) 455-8442 or contact us for a quote. Turnaround: 3-5 business days from our Brooklyn facility.
Beyond Occupant Safety
Protecting Property and Equipment
While the primary goal is always life safety, the benefits of a temperature rise door extend to protecting the building itself. By design, these doors limit the amount of heat that passes through them during a fire. This feature can be a game-changer for preserving valuable assets. Think about sensitive and expensive equipment in a hospital or laboratory located near a fire-rated stairwell. A standard fire door might stop the flames, but the intense radiant heat could still destroy everything on the "safe" side. A temperature rise door creates a much more effective thermal barrier, safeguarding not just equipment but also the structural integrity of adjacent walls and systems, which can significantly reduce repair costs and downtime after an incident.
Aiding Firefighter Response
Temperature rise doors also play a critical role in supporting first responders. During a fire, firefighters need to quickly assess conditions to plan their attack and rescue operations. A dangerously hot door serves as a clear warning that the environment on the other side is likely unsurvivable. By keeping the non-fire side of the door cooler, temperature rise doors allow emergency crews to safely approach and stage near the fire area. This is especially vital for emergency exit stairwells in high-rise buildings, which serve as the main artery for both occupant evacuation and firefighter access. A cooler, more tenable stairwell ensures a safer and more effective response, directly contributing to better outcomes for everyone involved.
NYC Code: Where Are Temperature Rise Doors Required?
The New York City Building Code (NYCBC) references IBC requirements and NFPA 80 for fire door assemblies. Temperature rise requirements apply primarily in the following locations:
For Stairwell Enclosures
In buildings where the stairwell serves as the required means of egress, doors opening into the stairwell enclosure -- fire tower stairs in particular -- require a 250F or 450F temperature rise rating. High-rise buildings (generally over 75 feet above grade in the NYCBC) typically require 250F doors on stairwells. The exact requirement depends on building height, occupancy classification, and whether the stairwell is pressurized.
For stairwells in buildings where pressurization offsets heat infiltration, the code may allow 450F instead of 250F. Confirm with the project's licensed fire protection engineer.
Fire ratings on stairwell enclosure doors in most NYC occupancy types run 90 minutes, so the full specification is often "90-minute, 250F temperature rise." For more on time ratings and where they apply, see our guide to fire door ratings explained.
For Exit Corridors
Exit corridor doors -- the doors separating exit access corridors from occupied spaces in commercial, institutional, and residential buildings -- often require a 450F or 650F temperature rise rating depending on occupancy. The NYCBC and its referenced standards require temperature rise control at these locations because corridor egress can involve occupants passing the doors during evacuation.
In R-2 occupancies (multi-family residential), corridor doors at dwelling unit entries commonly require a 450F temperature rise rating in addition to their fire time rating. If you manage apartment buildings with NYC fire code violations on corridor doors, confirm whether temperature rise is part of the corrective specification.
Code Exceptions and Nuances
While the NYCBC is specific about requiring temperature rise doors in locations like stairwells and exit corridors, building codes are rarely black and white. They often include exceptions and trade-offs based on other safety systems installed within a building. Understanding these nuances is crucial for property managers and contractors. It helps you avoid over-specifying a door and paying for a feature you don't legally need, or worse, under-specifying and facing failed inspections, project delays, and safety risks. One of the most significant factors that can alter temperature rise requirements is the presence of a building-wide automatic sprinkler system, which is a common point of confusion for many.
The Impact of Automatic Sprinkler Systems
Generally, if a building is fully protected by an automatic sprinkler system, the code may not require temperature rise doors. The logic is that sprinklers are designed to control a fire's growth, limiting the heat that reaches an egress door and making its surface temperature less of a critical safety factor. However, this is not a universal rule, especially in New York City. For the city's dense stock of high-rise buildings, stairwell enclosures are the primary, and often crowded, path for evacuation. Given the high stakes, the code may still mandate temperature rise fire-rated doors in these critical locations, even with sprinklers. Always confirm the exact requirements with your project's architect or a code consultant before placing an order.
NYC Temperature Rise Requirements at a Glance
| Location | Typical Fire Rating | Temperature Rise Requirement | Notes |
|---|---|---|---|
| High-rise stairwell enclosure (over 75 ft) | 90 minutes | 250F | Applies in non-pressurized stairwells; confirm with FPE |
| Stairwell enclosure (mid-rise) | 60-90 minutes | 450F | Varies by occupancy and stairwell type |
| Exit corridor (commercial/institutional) | 20-45 minutes | 450F or 650F | Occupancy-dependent; verify code section |
| Corridor door in residential (R-2) | 45 minutes | 450F | Common in NYC apartment buildings |
| 20-minute rated corridor | 20 minutes | 450F or 650F | Depends on wall rating and occupancy |
These are general guidelines based on IBC and NFPA 80 as adopted in NYC. Always verify the specific requirement with your architect or the NYC Department of Buildings (DOB) for the project at hand.
Construction and Design of Temperature Rise Doors
The ability of a temperature rise door to limit heat transfer isn't magic—it's a matter of specialized engineering and materials. Unlike a standard hollow metal door, which primarily blocks flames and smoke, a temperature rise door is built from the inside out to act as a thermal barrier. This unique construction affects everything from the door's weight and cost to the hardware it can support. Understanding these design elements is crucial for specifying the correct door for your project and ensuring it meets the strict fire and building codes in New York City. It’s not just about passing an inspection; it’s about creating a truly safe egress path for building occupants during an emergency.
Core Materials and Reinforcements
The key difference between a standard fire door and a temperature rise door lies in its core. To meet the strict heat transmission limits, these doors require a specially designed thermal core made from mineral-based or other heat-resistant materials. This core functions like insulation, absorbing and slowing the transfer of heat from the fire side to the non-fire side of the door. For example, a door with a 250F rating needs a more robust and dense core than one with a 650F rating. This specialized core material adds significant weight and cost to the door assembly. When planning a project, it's important to account for these factors, as the heavier door may also require more robust framing and hardware to function properly over its lifespan. We manufacture a range of fire-rated doors with different core options to meet these specific needs.
Glazing and Window Limitations
Adding windows, or "glazing," to a temperature rise door introduces a potential point of failure for heat transfer, so codes are very specific about what's allowed. For doors in critical locations like stairwells, any glazing is typically limited to 100 square inches. This glass must be "fire-protection-rated," meaning it's tested to stay in place and block flames. However, this type of glazing does not stop radiant heat. If a larger window is needed for visibility, you must use special "fire-resistance-rated" glazing. This advanced glass is engineered to also limit heat transfer to 450°F, just like the door itself. While this provides more design flexibility, it comes at a higher cost and must be specified correctly to ensure compliance and safety.
Size and Fit Specifications
When it comes to temperature rise doors, precision is everything. The rating—250F, 450F, or 650F—is not interchangeable. A 250F door offers the highest level of protection by imposing the strictest limit on heat transmission. You cannot substitute a 450F or 650F door in a location where the code demands a 250F rating; doing so will result in a failed inspection and a serious safety hazard. It is absolutely essential to confirm the required rating with your project's architect or a licensed fire protection engineer before ordering. Our team can manufacture commercial hollow metal doors to exact temperature rise specifications, but the initial requirement must come from the project's official plans to guarantee compliance with NYC building codes.
Do Temperature Rise Doors Also Stop Smoke?
It is worth distinguishing temperature rise requirements from smoke and draft control requirements, which are often specified together.
Smoke and draft control doors limit air leakage -- they carry a certification indicating the door assembly resists smoke movement at ambient temperatures. Temperature rise doors limit heat transmission. Both address different phases of a fire event.
Many stairwell and corridor doors in NYC buildings are required to meet both criteria: smoke and draft control AND temperature rise. This combination is common in high-rise occupancies. Universal Fire Doors manufactures assemblies meeting both requirements. If your specification calls for "smoke-and-draft/temperature rise" doors, confirm the assembly carries UL listings for both.
For a detailed breakdown of fire-rated steel door specifications for NYC buildings, see our fire-rated steel doors specification guide.
How to Identify Temperature Rise Requirements on Your Project
Temperature rise requirements appear in several places in construction documents and code review:
- Door schedule -- The architect's door schedule typically lists fire rating and temperature rise as separate columns. Look for "250TR," "450TR," or "650TR" next to the door's fire time rating.
- Specification section 08 11 13 -- The project manual's hollow metal doors and frames section spells out temperature rise requirements for each door type.
- NYC DOB plans examiner comments -- If a project received a code objection related to stairwell or egress doors, it may reference NYCBC section 717 or the applicable IBC table.
- Existing door label -- On an existing building, the UL or WHI/Intertek label on the door edge records the fire rating and, if applicable, the temperature rise rating. Labels read something like "90 MIN / 250F TEMPERATURE RISE."
If you are replacing existing fire doors and cannot locate the label or original specification, call Universal Fire Doors at (718) 455-8442. Our team can help identify the correct replacement specification based on building type, floor, and occupancy.
Reading the Label Correctly
The key to verifying a door's rating is its certification label, which you can usually find on the hinge edge of the door or at the top. This small metal plate contains critical safety information. For a temperature rise door, the label will explicitly state its performance. It won't be vague. You should see clear language indicating that the door limits heat transfer to a specific temperature within a set time, such as "250F in 30 minutes." This tells you that during the first 30 minutes of a fire test, the temperature on the non-fire side of the door did not rise more than 250 degrees Fahrenheit above the starting temperature. It’s a straightforward pass/fail system, and the label is the official record of that test result.
How to Spot a Misleading Label
It's easy to misinterpret some labels, which can lead to installing a non-compliant door. Be on the lookout for phrasing like, "Temperature Rise Exceeds 650 degrees Fahrenheit at 30 minutes." At first glance, this might seem like it's describing a 650F rating, but it actually means the opposite. This language indicates the door failed the test because it got too hot, too fast, surpassing the maximum allowable temperature rise. A compliant door will state that it limits the temperature rise, not that it exceeds a certain threshold. This small difference in wording is everything when it comes to safety and code compliance, so read carefully before you purchase or approve an installation.
The Importance of Professional Inspection
While reading the label is a great first step, it doesn't tell the whole story. Fire safety compliance involves the entire door assembly—the door, the frame, the hardware, and the installation itself. A perfectly rated door installed in the wrong frame or with non-compliant hardware is a failed assembly. Furthermore, building codes can be complex, and New York City often has specific requirements that go beyond the general standards. Simply ordering a door based on a label might not be enough to pass an inspection by the NYC Department of Buildings. A professional assessment ensures every component works together to meet the stringent local codes for your specific building and occupancy type, from hospital doors to apartment entryways.
Working with Certified Professionals
To guarantee compliance and safety, it’s always best to work with certified professionals. A Certified Fire Door Assembly Inspector (CFDAI) or a qualified installation team can verify that your new or existing doors meet every requirement. They understand the nuances of NFPA 80 and local NYC codes, ensuring the correct temperature rise door is specified and installed correctly. At Universal Fire Doors, our OSHA-certified crews are fully licensed and insured, specializing in fire-rated doors for NYC buildings. Relying on experts removes the guesswork, protects your property and tenants, and helps you avoid costly fines and project delays from failed inspections. It’s about getting the job done right the first time.
How Long Does It Take to Get a Temperature Rise Door in NYC?
Temperature rise doors are not stock items. The specialized thermal cores require custom fabrication, and the door must be manufactured to the exact opening dimensions and hardware prep of each individual location. This makes lead time a real project variable -- particularly during NYC building renovation work where existing openings rarely conform to standard dimensions.
Universal Fire Doors manufactures custom temperature-rise core doors in our Brooklyn facility. Standard lead time for custom temperature rise doors is 3-5 business days -- compared to the 2-3 week lead time typical from suppliers that outsource manufacturing. Expedited production (1-3 business days) is available for urgent projects where capacity allows.
We manufacture temperature rise doors in all gauges (12, 14, 16, 18 gauge steel) with all three thermal core ratings: 250F, 450F, and 650F. UL fire ratings from 20 minutes through 3 hours are available. Stainless steel temperature rise doors carry a 12-day standard lead time.
For complete project specs including hardware, frames, and installation, see our overview of what is a fire rated door and our guide to fire-rated steel door specifications.
Need temperature rise doors for a stairwell, corridor, or egress opening in your NYC building? Universal Fire Doors manufactures to spec in 3-5 business days. Call (718) 455-8442 or request a free estimate online.
Frequently Asked Questions
What is the difference between a fire rating and a temperature rise rating?
A fire rating (20, 45, 60, 90 minutes) tells you how long the door assembly resists fire penetration and structural failure during a standardized test. A temperature rise rating (250F, 450F, 650F) is an additional requirement specifying the maximum heat that can transmit through the door to the unexposed side at 30 minutes. Both can appear on the same door: for example, "90-minute, 250F temperature rise."
Do all fire doors need a temperature rise rating?
No. Temperature rise requirements apply only to specific locations -- primarily stairwell enclosures and exit corridors. Most fire doors in partition walls and tenant separations carry only a time rating with no temperature rise requirement. Check the project's door schedule and specification for your specific openings.
Which temperature rise rating is most restrictive?
250F is the most restrictive. A lower number means the door must limit heat transmission more aggressively -- requiring a denser, more effective thermal core. When you see 250F specified, it is typically for high-occupancy egress paths like pressurized or non-pressurized high-rise stairwells.
Can I substitute a 250F door where a 450F is required?
Yes. A higher-performing temperature rise door (250F) is always acceptable where a less restrictive rating (450F or 650F) is required. You cannot substitute in the other direction -- a 650F door does not satisfy a 250F requirement.
How fast can I get custom temperature rise doors in NYC?
Universal Fire Doors manufactures custom temperature rise doors (250F, 450F, 650F) in Brooklyn with 3-5 business day standard turnaround, and expedited production is available in 1-3 business days when capacity allows. This is significantly faster than the 2-3 week industry average for custom temperature rise doors.
Are temperature rise doors required for NYC Local Law 11 or Local Law 111 compliance?
Local Law 11 (facade inspection) does not involve door specifications. Local Law 111 (self-closing doors in R-1/R-2 occupancies) does require self-closing mechanisms on certain corridor doors, but temperature rise requirements are determined by the NYC Building Code and NFPA 80 based on building type and location within the building -- not by Local Law 111 directly. Consult the project specifications or a licensed fire protection engineer to confirm whether temperature rise is required for your compliance work.
Key Takeaways
- Temperature rise is a separate safety rating: A door's fire rating (like 90 minutes) measures how long it resists flames, while its temperature rise rating (250F, 450F, or 650F) measures how well it insulates against heat to keep escape routes usable.
- Code dictates the rating you need: NYC building codes require specific temperature rise doors in critical areas like stairwells and exit corridors to ensure safe evacuation; using the wrong rating will lead to failed inspections and safety risks.
- Specialized construction affects project planning: These doors have special thermal cores that make them heavier, more expensive, and custom-fabricated, so it's vital to confirm the exact rating with an architect and plan for manufacturing time.
Related Articles
Ready to Get Started?
NYC's trusted commercial fire door specialists — fast response, code-compliant work.
What NYC Property Owners Say
UFD replaced 40 fire doors in our office tower on schedule. Their team knew every code requirement and coordinated around our tenants seamlessly.
— Robert M. — Property Manager, Midtown Manhattan
Called them for an emergency repair after a failed inspection. They were on-site within hours and got us back to compliance the same day.
— Angela T. — Facilities Director, Brooklyn Medical
Transparent pricing, expert crew, and the documentation they provided for our building file was perfect. Best contractor experience in NYC.
— James W. — Building Owner, Queens
Frequently Asked Questions
What Is a Temperature Rise Door?
A temperature rise door is a fire-rated door assembly that must also limit the heat transmitted through the door to the unexposed (egress) side. Standard fire-rated doors are tested and rated only for…
Is a Temperature Rise Rating the Same as a Fire Rating?
A standard fire door carries a time rating: 20, 45, 60, 90, or 180 minutes. That rating tells you how long the assembly resists fire penetration, structural failure, and smoke passage. A 90-minute fir…
Breaking Down the 3 Temperature Rise Ratings
Here is how the three ratings differ in terms of what they allow and where they are used:
Why Do Temperature Rise Requirements Exist?
During a fire, occupants may need to approach a stairwell or corridor door to determine if the path is safe for evacuation. If the door surface is dangerously hot, contact alone can cause injury, and …
NYC Code: Where Are Temperature Rise Doors Required?
The New York City Building Code (NYCBC) references IBC requirements and NFPA 80 for fire door assemblies. Temperature rise requirements apply primarily in the following locations:
Emergency Fire Door Service — NYC 24/7
Failed inspection? Damaged door? We respond across all five boroughs.
📞 Call (718) 455-8442Need fire door help in NYC?
We manufacture & install in 3–5 days. Violations, replacements & inspections across all 5 boroughs.